• G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
  • G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
  • G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
  • G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
  • G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
  • G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump

G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump

Compressor: Panasonic Hybrid Inverter &Evi Type
Cooling Efficiencies up to: 18.5/13eer
Heating Efficiencies up to: 6.5cop
Samples:
US$ 887/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump pictures & photos
G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
US $887 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
G1-K05WDH/2P
Compressor Type
Inverter
Refrigerant Type
R32
ERP Level
a+++
Heat Exchanger
Plate Exchanger
Water Pump Brand
Optional
Water Connection
1"
Water Pressure Drop
10kpa
Water Pump Head
8m
Water Pump Quantity
Optional
Water Pump Type
Optional
Pressure Sdeakonor 1
0-20bar
Pressure Sdeakonor 2
0-45bar
Transport Package
Plywood Box
Specification
600*500*650
Trademark
Deakon, OEM
Origin
China
HS Code
8418612090
Production Capacity
500000pieces/Year

Packaging & Delivery

Package Size
600.00cm * 500.00cm * 650.00cm
Package Gross Weight
60.000kg

Product Description

G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
G1 6KW DC Inverter Water to Water Ground Source Geothermal Heat Pump

SPECIFICATION
Model
K05-WDH
K12-WDH
K18-WDH
K24-WDH
K38-WDH
Heating Capacity
Range*
kW
3 ~ 6 3.9 ~ 13 5.85 ~ 19.5 7.5 ~ 25 11.4 ~ 38
BTU/h
10236 ~ 20472 13307 ~ 44356 19960 ~ 66534 25590 ~ 85300 38897 ~ 129656
Heating Power Input
Range
kW 0.5 ~ 1.4 0.7 ~ 3.0 1.1 ~ 4.6 1.4 ~ 6.0 2.1 ~ 9.0
COP
/ 5.5 ~ 4.2 5.5 ~ 4.2 5.5 ~ 4.2 5.5 ~ 4.2 5.5 ~ 4.2
Cooling Capecity Range*
kW 1.8 ~ 5 3.51 ~ 11.7 5.265 ~ 17.55 6.75 ~ 22.5 10.26 ~ 34.2
BTU/h 6142 ~ 17060 11976 ~ 39920 17964 ~ 59881 23031 ~ 76770 35007 ~ 116690
Cooling Power Input
Range
kW 0.36 ~ 1.25 0.7 ~ 2.93 1.05 ~ 4.39 1.35 ~ 5.63 2.05 ~ 8.55
EER
/
5 ~ 4 5 ~ 4 5 ~ 4 5 ~ 4 5 ~ 4
Frequency
Hz
30 ~ 90 30 ~ 90 30 ~ 90 30 ~ 90 30 ~ 90
ErP level(35ºC)
/
A+++
A+++ A+++ A+++ A+++
ErP level(55ºC)
/
A+
A+
A+
A+
A+
Power Supply
V/Hz
1P/220-240/50-60Hz
1P/220-240/50-60Hz
1P/220-240/50-60Hz
3P/380V/50-60Hz
3P/380V/50-60Hz
Electric Heater
kW
/ / / / /
Refrigerant Type
/
R32 R32 R32 R32 R32
Refrigerant Quantity
kg
1.35 1.8 2.1 3.0 3.5
Compressor Brand
/ Panasonic Panasonic Panasonic Panasonic Panasonic
Compressor Type
/
Inverter
Inverter
Inverter
Inverter
Inverter
Heat Exchanger
Type
Plate Exchanger
Plate Exchanger
Plate Exchanger
Plate Exchanger
Plate Exchanger
Water Pump Brand
/
Optional
Optional
Optional
Optional
Optional
Water Connection
/
1"
1"
1"
1"
1"
Water Flow of Source Side
m³/h
1,7
3,7
5,6
7,2
10,9
Water Flow of User Side
m³/h
1,0
2,2
3,4
4,3
6,5
Water Pressure Drop
kPa
10
10
10
10
10
Water Pump Head
m
8 8 8 8 8
Water Pump Quantity*
/
Optional
Optional
Optional
Optional
Optional
Water Pump Type
/ Optional Optional Optional Optional Optional
Pressure SDEAKONor 1
Bar
0-20
0-20 0-20 0-20 0-20
Pressure SDEAKONor 2
Bar
0-45
0-45
0-45
0-45
0-45
Noise
dB(A)
42
42
42
42
46
Net Weight
kg
58
90 100 116 135
Gross Weight
kg 77 117 128 145 158
Net DimDEAKONion(L/
mm
600*500*650
600*500*650
600*500*650
600*500*650
600*500*650
Shippping
DimDEAKONion(L/W/H)
mm
650*550*750
650*550*750
650*550*750
650*550*750
650*550*750
Operation Ambient
Temp.
ºC
-25~43ºC
-25~43ºC
-25~43ºC
-25~43ºC
-25~43ºC
G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat PumpG1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump pictures & photos
G1 6kw DC Inverter Water to Water Ground Source Geothermal Heat Pump
US $887 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
36
Year of Establishment
2010-03-22