Basic Info.

Model NO.
MFP-34KM-(Q)MK1
Usage
Room
Indoor Machine Noise
24-35dB
Certification
CE, RoHS
China Energy Efficiency Standard
Level 1
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Production Capacity
2000/Month

Product Description

M style 4 way cassette type fan coil unit
 

4-way air flowing, which can uniform temperature distribution in the room

 

Air volume range: 380m³/h~2720m³/h

 

Cooling capacity range: 2000W~15000W

 

remote controller is standard, 4-pipe system is optional.
Deakon M Style 4 Way Cassette Type Fan Coil

model(2 tube system) MFP-34KM-(Q)MK1 MFP-51KM-(Q)MK1 MFP-68KM-(Q)MK1 MFP-80KM-(Q)MK1 MFP-85KM-(Q)MK2 MFP-102KM-(Q)MK2 MFP-136KM-(Q)MK2 MFP-136KM-(Q)MK3 MFP-153KM-(Q)MK3 MFP-170KM-(Q)MK3 MFP-204KM-(Q)MK3 MFP-238KM-(Q)MK3
model FP-34KM-(Q)M1 FP-51KM-(Q)M1 FP-68KM-(Q)M1 FP-80KM-(Q)M1 FP-85KM-(Q)M2 FP-102KM-(Q)M2 FP-136KM-(Q)M2 FP-136KM-(Q)M3 FP-153KM-(Q)M3 FP-170KM-(Q)M3 FP-204KM-(Q)M3 FP-238KM-(Q)M3
model of panel MB-SD11K1 MB-SD11K2 MB-SD11K3
power supply 220V,50Hz,1Ph
air volume H m3/h 380 550 680 780 880 1050 1300 1380 1550 1750 2050 2200
M 300 440 540 620 700 840 1040 1100 1240 1400 1640 1760
L 230 330 410 470 530 630 780 830 930 1050 1230 1320
static pressure Pa 0 0 0 0 0 0 0
 

 
0 0 0
cooling capacity TH H W 2000 3000 3800 4200 4900 5800 7000 7500 8100 9800 11000 12000
BTU/h 6824 10236 12966 14330 16719 19790 23884 25590 27637 33438 37532 40944
SH W 1400 2200 2850 3300 3500 4250 5250 5500 5880 7150 8250 9100
BTU/h 4777 7506 9724 11260 11942 14501 17913 18766 20060 24396 28149 31049
TH M W 1700 2550 3250 3550 4150 4950 5950 6400 6650 8350 9350 10200
SH W 1150 1800 2350 2650 2850 3500 4350 4550 4700 5950 6850 7650
TH L W 1400 2050 2600 2900 3400 4000 4850 5200 5420 6750 7600 8300
SH W 950 1400 1850 2100 2300 2800 3450 3600 3850 4700 5450 6000
heating capacity H W 3100 4700 5900 6500 7600 9000 10900 11600 12200 15200 17100 18600
M W 2650 4000 5000 5550 6450 7650 9250 9850 10300 12900 14550 15800
L W 2100 3150 3950 4350 5100 6050 7300 7750 8140 10200 11450 12450
noise H 0Pa dB(A) 39 42 44 46 42 46 48 46 48 47 50 51
power input H 0Pa W 40 50 58 60 70 95 125 130 145 160 190 210
waterflow volume m3/h 0.34 0.51 0.65 0.72 0.83 0.99 1.19 1.28 1.38 1.67 1.87 2.04
water pressure dropping kPa 11 13 22 25 18 25 30 23 23 28 33 42
dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
dimension of water drain pipe mm ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26
 

 
¢26 ¢26 ¢26
net dimension unit L×W×H     mm 592*592*242
 
750*750*242 840*840*242 840*840*292
panel 650*650*40
 
850*850*40 950*950*40 950*950*40
net weight unit kg 17 18 18 18.5 22 23 23 25 26 27 27

 
panel
 
2.2 4.2 5
model(2 tube system) MFP-34KM4-(Q)MK1 MFP-51KM4-(Q)MK1 MFP-68KM4-(Q)MK1 MFP-80KM4-(Q)MK1 MFP-85KM4-(Q)MK2 MFP-102KM4-(Q)MK2 MFP-136KM4-(Q)MK2 MFP-136KM4-(Q)MK3 MFP-153KM4-(Q)MK3 MFP-170KM4-(Q)MK3 MFP-204KM4-(Q)MK3 MFP-238KM4-(Q)MK3
model FP-34KM4-(Q)M1 FP-51KM4-(Q)M1 FP-68KM4-(Q)M1 FP-80KM4-(Q)M1 FP-85KM4-(Q)M2 FP-102KM4-(Q)M2 FP-136KM4-(Q)M2 FP-136KM4-(Q)M3 FP-153KM4-(Q)M3 FP-170KM4-(Q)M3 FP-204KM4-(Q)M3 FP-238KM4-(Q)M3
model of panel MB-SD11K1 MB-SD11K2 MB-SD11K3
power supply 220V,50Hz,1Ph
air volume H m3/h 360 520 650 740 840 1000 1240 1320 1480 1660 1950 2090
M 290 420 510 590 670 800 990 1050 1180 1330 1560 1670
L 220 310 390 450 500 600 740 790 885 1000 1170 1250
static pressure Pa 0 0 0 0 0 0 0 0 0 0 0 0
cooling capacity TH H W 1950 2950 3700 4100 4800 5700 6850 7350 7940 9600 10800 11750
BTU/h 6700 10050 12700 14050 16400 19400 23400 25100 27100 32750 36800 40150
SH W 1350 2150 2800 3250 3450 4150 5150 5400 5773 7000 8100 8900
BTU/h 4700 7350 9550 11050 11700 14200 17550 18400 19650 23900 27600 30450
TH M W 1650 2500 3200 3500 4050 4850 5850 6250 6490 8200 9150 10000
SH W 1150 1750 2300 2600 2800 3450 4250 4450 4600 5850 6700 7500
TH L W 1350 2000 2550 2850 3350 3900 4750 5100 5315 6600 7450 8150
SH W 950 1350 1800 2050 2250 2750 3400 3550 3800 4600 5350 5900
heating capacity H W 1950 3000 3750 4150 4850 5750 6950 7400 7780 9700 10900 11850
M W 1700 2550 3200 3550 4100 4850 5900 6250 6535 8200 9250 10050
L W 1350 2000 2500 2750 3250 3850 4650 4950 5200 6500 7300 7950
noise H 0Pa dB(A) 39 42 44 46 42 46 48 46 48 47 50 51
power input H 0Pa W 40 50 58 60 70 95 125 130 145 160 190 210
waterflow volume Cooling m3/h 0.33 0.5 0.64 0.71 0.81 0.97 1.17 1.25 1.4 1.64 1.83 2
Heating 0.22 0.33 0.42 0.46 0.54 0.64 0.77 0.82 0.86 1.08 1.21 1.32
water pressure dropping Cooling kPa 11 13 22 25 18 25 30 23 23 28 33 42
Heating 7 8 13 14 11 15 21 15 15 19 23 26
dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
dimension of water drain pipe mm ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26
 

 
¢26 ¢26 ¢26
net dimension unit L×W×H     mm 592*592*242
 
750*750*242 840*840*242 840*840*292
panel 650*650*40
 
850*850*40 950*950*40 950*950*40
net weight unit kg 19 20 20 20.5 24.5 25.5 25.5 27.5 29.5 29.5 30